肝胆特异性MRI对比剂临床应用(第2版)
上QQ阅读APP看书,第一时间看更新

参考文献

1.Im WH,Song JS,Park EH,et al. Transient severe motion in the arterial phase during gadoxetate disodium-enhanced MR imaging:evaluation of patients with multiple MR examinations. Abdom Radiol(NY),2017,42(10):2393-2401.
2.Davenport MS,Bashir MR,Pietryga JA,et al. Dose-toxicity relationship of gadoxetate disodium and transient severe respiratory motion artifact. AJR Am J Roentgenol,2014,203(4):796-802.
3.Davenport MS,Malyarenko DI,Pang Y,et al. Effect of Gadoxetate Disodium on Arterial Phase Respiratory Waveforms Using a Quantitative Fast Fourier Transformation-Based Analysis. AJR Am J Roentgenol,2017,208(2):328-336.
4.Haradome H,Grazioli L,Tsunoo M,et al. Can MR fluoroscopic triggering technique and slow rate injection provide appropriate arterial phase images with reducing artifacts on gadoxetic acid-DTPA(Gd-EOB-DTPA)-enhanced hepatic MR imaging? J Magn Reson Imaging,2010,32(2):334-340.
5.Kanki A,Tamada T,Abe T,et al. Relationship between transient severe motion of the liver in gadoxetic acid or iodinated contrast agent-enhanced imaging and arterial oxygen saturation and heart rate changes. Magn Reson Imaging,2018,53:77-81.
6.Kim SY,Park SH,Wu EH,et al. Transient respiratory motion artifact during arterial phase MRI with gadoxetate disodium:risk factor analyses. AJR Am J Roentgenol,2015,204(6):1220-1227.
7.Li H,Xiao Y,Wang S,et al. TWIST-VIBE five-arterial-phase technology decreases transient severe motion after bolus injection of Gd-EOB-DTPA. Clin Radiol,2017,72(9):800 e801-800 e806.
8.Namimoto T,Shimizu K,Nakagawa M,et al. Reducing artifacts of gadoxetate disodium-enhanced MRI with oxygen inhalation in patients with prior episode of arterial phase motion:intra-individual comparison. Clin Imaging,2018,52:11-15.
9.Polanec SH,Bickel H,Baltzer PAT,et al. Respiratory motion artifacts during arterial phase imaging with gadoxetic acid:Can the injection protocol minimize this drawback? J Magn Reson Imaging,2017,46(4):1107-1114.
10.Ringe KI,von Falck C,Raatschen HJ,et al. Evaluation of transient respiratory motion artifact at gadoxetate disodiumenhanced MRI-Influence of different contrast agent application protocols. PLoS One,2018,13(7):e0200887.
11.Song JS,Choi EJ,Park EH,et al. Comparison of transient severe motion in gadoxetate disodium and gadopentetate dimeglumine-enhanced MRI:effect of modified breath-holding method. Eur Radiol,2018,28(3):1132-1139.
12.Xiao YD,Ma C,Liu J,et al. Transient severe motion during arterial phase in patients with Gadoxetic acid administration:Can a five hepatic arterial subphases technique mitigate the artifact? Exp Ther Med,2018,15(3):3133-3139.
13.Bashir MR,Castelli P,Davenport MS,et al. Respiratory motion artifact affecting hepatic arterial phase MR imaging with gadoxetate disodium is more common in patients with a prior episode of arterial phase motion associated with gadoxetate disodium. Radiology,2015,274(1):141-148.
14.Pietryga JA,Burke LM,Marin D,et al. Respiratory motion artifact affecting hepatic arterial phase imaging with gadoxetate disodium:examination recovery with a multiple arterial phase acquisition. Radiology,2014,271(2):426-434.
15.Motosugi U,Bannas P,Bookwalter CA,et al. An Investigation of Transient Severe Motion Related to Gadoxetic Acidenhanced MR Imaging. Radiology,2016,279(1):93-102.
16.McClellan TR,Motosugi U,Middleton MS,et al. Intravenous Gadoxetate Disodium Administration Reduces Breath-holding Capacity in the Hepatic Arterial Phase:A Multi-Center Randomized Placebo-controlled Trial. Radiology,2017,282(2):361-368.
17.Davenport MS,Viglianti BL,Al-Hawary MM,et al. Comparison of acute transient dyspnea after intravenous administration of gadoxetate disodium and gadobenate dimeglumine:effect on arterial phase image quality. Radiology,2013,266(2):452-461.
18.Davenport MS,Caoili EM,Kaza RK,et al. Matched within-patient cohort study of transient arterial phase respiratory motionrelated artifact in MR imaging of the liver:gadoxetate disodium versus gadobenate dimeglumine. Radiology,2014,272(1):123-131.
19.Denecke T,Steffen IG,Agarwal S,et al. Appearance of hepatocellular adenomas on gadoxetic acid-enhanced MRI. Eur Radiol,2012,22(8):1769-1775.
20.Chung SH,Kim MJ,Choi JY,et al. Comparison of two different injection rates of gadoxetic acid for arterial phase MRI of the liver. J Magn Reson Imaging,2010,31(2):365-372.
21.Rohrer M,Bauer H,Mintorovitch J,et al. Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol,2005,40(11):715-724.
22.Gruber L,Rainer V,Plaikner M,et al. CAIPIRINHA-Dixon-TWIST(CDT)-VIBE MR imaging of the liver at 3.0T with gadoxetate disodium:a solution for transient arterial-phase respiratory motion-related artifacts? Eur Radiol,2018,28(5):2013-2021.
23.Qu J,Han S,Zhang H,et al. Arterial Phase with CAIPIRINHA-Dixon-TWIST(CDT)-Volume-Interpolated Breath-Hold Examination(VIBE)in Detecting Hepatic Metastases. Transl Oncol,2017,10(1):46-53.
24.Qu J,Han S,Zhang H,et al. Improved Detection of Recurrent Hepatocellular Carcinomas in Arterial Phase With CAIPIRINHA-Dixon-TWIST-Volumetric Interpolated Breath-Hold Examination. Invest Radiol,2016,51(10):602-608.
25.Kazmierczak PM,Theisen D,Thierfelder KM,et al. Improved detection of hypervascular liver lesions with CAIPIRINHADixon-TWIST-volume-interpolated breath-hold examination. Invest Radiol,2015,50(3):153-160.
26.Chandarana H,Block TK,Ream J,et al. Estimating liver perfusion from free-breathing continuously acquired dynamic gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid-enhanced acquisition with compressed sensing reconstruction.Invest Radiol,2015,50(2):88-94.
27.Bashir MR,Merkle EM. Improved liver lesion conspicuity by increasing the flip angle during hepatocyte phase MR imaging.Eur Radiol,2011,21(2):291-294.
28.Elsayes KM,Kielar AZ,Elmohr MM,et al. White paper of the Society of Abdominal Radiology hepatocellular carcinoma diagnosis disease-focused panel on LI-RADS v2018 for CT and MRI. Abdom Radiol(NY),2018,43(10):2625-2642.
29.Gomi T,Nagamoto M,Hasegawa M,et al. Radial MRI during free breathing in contrast-enhanced hepatobiliary phase imaging. Acta Radiol,2014,55(1):3-7.
30.Cho ES,Yu JS,Park AY,et al. Feasibility of 5-minute delayed transition phase imaging with 30 degrees flip angle in gadoxetic acid-enhanced 3D gradient-echo MRI of liver,compared with 20-minute delayed hepatocyte phase MRI with standard 10 degrees flip angle. AJR Am J Roentgenol,2015,204(1):69-75.
31.Cohen-Hallaleh V,Guo L,Hosseini-Nik H,et al. Does injection flow rate have an impact on arterial phase image degradation in liver MRI? A comparison of gadoxetic acid versus gadobutrol. Clin Radiol,2017,72(11):994 e991-994 e998.
32.Liang M,Zhao J,Xie B,et al. MR liver imaging with Gd-EOB-DTPA:The need for different delay times of the hepatobiliary phase in patients with different liver function. Eur J Radiol,2016,85(3):546-552.
33.Tamada T,Ito K,Yoshida K,et al. Comparison of three different injection methods for arterial phase of Gd-EOB-DTPA enhanced MR imaging of the liver. Eur J Radiol,2011,80(3):e284-288.
34.Gutzeit A,Matoori S,Froehlich JM,et al. Reduction in respiratory motion artefacts on gadoxetate-enhanced MRI after training technicians to apply a simple and more patient-adapted breathing command. Eur Radiol,2016,26(8):2714-2722.
35.Kim YC,Min JH,Kim YK,et al. Intra-individual comparison of gadolinium-enhanced MRI using pseudo-golden-angle radial acquisition with gadoxetic acid-enhanced MRI for diagnosis of HCCs using LI-RADS. Eur Radiol,2019,29(4):2058-2068.
36.Song JS,Choi EJ,Park EH,et al. Comparison of transient severe motion in gadoxetate disodium and gadopentetate dimeglumine-enhanced MRI:effect of modified breath-holding method. Eur Radiol,2018,28(3):1132-1139.
37.Weiss J,Taron J,Othman AE,et al. Feasibility of self-gated isotropic radial late-phase MR imaging of the liver. Eur Radiol,2017,27(3):985-994.
38.Chandarana H,Block TK,Ream J,et al. Estimating liver perfusion from free-breathing continuously acquired dynamic gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid-enhanced acquisition with compressed sensing reconstruction.Invest Radiol,2015,50(2):88-94.
39.Chandarana H,Feng L,Ream J,et al. Respiratory Motion-Resolved Compressed Sensing Reconstruction of Free-Breathing Radial Acquisition for Dynamic Liver Magnetic Resonance Imaging. Invest Radiol,2015,50(11):749-756.
40.Kim J,Kim BS,Lee JS,et al. Optimization of the Flip Angle and Scan Timing in Hepatobiliary Phase Imaging Using T1-Weighted,CAIPIRINHA GRE Imaging. Investigative Magnetic Resonance Imaging,2018,22(1):1.
41.Iyama Y,Nakaura T,Yokoyama K,et al. Comparison of the Timing of Hepatic Arterial Phase and Image Quality Using Test-Bolus and Bolus-Tracking Techniques in Gadolinium-Ethoxybenzyl-Diethylenetriamine Pentaacetic Acid-Enhanced Hepatic Dynamic Magnetic Resonance Imaging. J Comput Assist Tomogr,2017,41(4):638-643.
42.Haradome H,Grazioli L,Al manea K,et al. Gadoxetic acid disodium-enhanced hepatocyte phase MRI:can increasing the flip angle improve focal liver lesion detection? J Magn Reson Imaging,2012,35(1):132-139.
43.Haradome H,Grazioli L,Tsunoo M,et al. Can MR fluoroscopic triggering technique and slow rate injection provide appropriate arterial phase images with reducing artifacts on gadoxetic acid-DTPA(Gd-EOB-DTPA)-enhanced hepatic MR imaging? J Magn Reson Imaging,2010,32(2):334-340.
44.Huh J,Kim SY,Yeh BM,et al. Troubleshooting Arterial-Phase MR Images of Gadoxetate Disodium-Enhanced Liver. Korean J Radiol,2015,16(6):1207-1215.
45.Li RK,Palmer SL,Zeng MS,et al. Detection of Endogenous Iron Reduction during Hepatocarcinogenesis at Susceptibility-Weighted MR Imaging:Value for Characterization of Hepatocellular Carcinoma and Dysplastic Nodule in Cirrhotic Liver.PLoS One,2015,10(11):e0142882.
46.Cieszanowski A,Podgorska J,Rosiak G,et al. Gd-EOB-DTPA-Enhanced MR Imaging of the Liver:The Effect on T2 Relaxation Times and Apparent Diffusion Coefficient(ADC).Pol J Radiol,2016,81:103-109.
47.Guglielmo FF,Mitchell DG,Gupta S. Gadolinium contrast agent selection and optimal use for body MR imaging. Radiol Clin North Am,2014,52(4):637-656.
48.ChandaranaH,Block TK,Ream J,et al. Estimating LiverPerfusion From Free-breathing Continuously Acquired Dynamic Gd-EOB-DTPAEnhanced Acquisition With Compressed Sensing Reconstruction. Invest Radiol,2015,50(2):88-94.
49.Riffel P,Zoellner FG,Budjan J,et al. One-Stop Shop:Free-Breathing Dynamic Contrast-EnhancedMagnetic Resonance Imaging of the Kidney Using Iterative Reconstruction andContinuous Golden-Angle Radial Sampling. Invest Radiol,2016,(10):1097.
50.RosenkrantzA B,Geppert C,Grimm R,et al. Dynamic contrast-enhanced MRI of the prostate with highspatiotemporal resolution using compressed sensing,parallel imaging,andcontinuous golden-angle radial sampling:Preliminary experience.Journal of MagneticResonance Imaging,2015,41(5):1365-1373.
51.Kim YK,Lin WC,Sung K,et al. Reducing Artifacts during Arterial Phase of Gadoxetate Disodium-enhanced MR Imaging:Dilution Method versus Reduced Injection Rate. Radiology,2017,283(2):429-437.
52.杨正汉,冯逢,王霄英.磁共振成像技术指南.北京:人民卫生出版社,2010.
53.马文婷,黎金葵,翟亚楠,等.CAIPIRINHA-Dixon-TWIST-VIBE技术诊断小肝癌的研究进展.中国医学影像技术,2017,33(08):1277-1280.
54.韩玉娟,于长路,贾科峰,等.不同注射流率及动脉期期相选择对肝脏普美显增强MRI图像质量的影响.临床放射学杂志,2016,35(01):138-142.